Low Voltage Power Cable
Brand : Yiteng Cable
Product origin : China
Delivery time : Within 10-20 Days After Receiving Payment
Supply capacity : 100000m/week
Insulation: PVC or XLPE
Structure:
1.non armoured low voltage power cable
2. steel tape armoured low voltage power cable
3. steel wire armoured low voltage power cable
PVC Insulation Rated voltage 1KV(1.2KV) and 3KV(3.6KV) PVC insulated Flame retardant and Fire resistant power cables
Product standard
PVC insulated Flame retardant and Fire resistant Power cables are fixed laid in the circuit with frequency 50HZ and voltage to 3.6/6KV.
We can produce Flame retardant and Fire resistant power cables according to standard GB/T19666,Grade A,B,C or D.
Rated Voltage 0.6/1KV and 3.6/6KV.
Conductor of cables can be Copper and Aluminum.
The cables can be single core, two cores, three cores, four cores,(include three main cores and neutral) five cores(include three main cores and two neutral ;four. main cores and one neutral). The cables can be with armor and without armor.
We can produce cables with PVC outer sheath, Flame retardant PVC outer sheath or with fire resistant insulation. The cables are produced according to GB/T12706(eqv IEC60502) and GB/T18380-2001(eqv IEC60332) or GB/T19216(eqv IEC60331) and or the BS, DIN, or other international standards. And we also design and produce cables according to the requirement of our clients.
Application:
1.Long term working temperature is to 70℃.
2.The highest conductor temperature is not more than 160℃(lasting time not over 5 seconds)
3.Laying temperature not less than 0℃and the drop height is our of consideration.
4.The cable with chemical stability, anti acid, anti alkali, anti oil, anti organic solvent, not easy to be burning.
5.Easy for installation, easy bending and light.
6.Bending ratio as follow
Item | Single core | Three core | ||
Non armor | With armor | Non armor | With armor | |
Min bending radius during installation | 20D | 15D | 15D | 12D |
Near joint box or cable terminal, bending with care and use template. | 15D | 12D | 12D | 10D |
Note:D is the diameter of cable. |
Cable type and name
Type | Description |
VV,VLV | PVC insulated and sheathed power cable with Cu/Al core |
VY,VLY | PVC insulated and PE sheathed power cable with Cu/Al core |
VV22,VLV22 | Steel tape armored, PVC insulated and sheathed power cable with Cu/Al core |
VV23,VLV23 | Steel tape armored, PVC insulated and PE sheathed power cable with Cu/Al core |
VV32,VLV32 | Steel wire armored, PVC insulated and sheathed power cable with Cu/Al core |
VV33,VLV33 | Steel wire armored, PVC insulated and PE sheathed power cable with Cu/Al core |
VV42,VLV42 | Steel wire armored, PVC insulated and sheathed power cable with Cu/Al core |
VV43,VLV43 | Steel wire armored, PVC insulated and PE sheathed power cable with Cu/Al core |
Normal cross section of the conducting core (mm²)
(1)(Main core)
1/1.5/2.5/4/6/10/25/35/50/70/95/120/150/185/240/300/400/500/630
(2) 3+1(Neutral core)
1.5/2.5/4/6/10/16/25/35/50/70/95/120/150/240/300
(3) 3+2(Neutral core)
1.5/2.5/4/6/10/16/25/35/50/70/95/120/150/240/300
XLPE Insulation Rated voltage 1KV(1.2KV) and 3KV(3.6KV) XLPE insulated Flame retardant and Fire resistant power cables
Product standard
XLPE insulated Flame retardant and Fire resistant Power cables are fixed laid in the circuit with frequency 50Hz and voltage up to 3.6/6KV.
We can produce Flame retardant and Fire resistant power cables according to standard GB/T19666-2002, Grade A,B,C or D.
Rated voltage 0.6/1KV and 3.6/6KV.
Conductor of cables can be Copper and Aluminum.
The cables can be single core, two cores ,three cores, four cores(include three main cores and one neutral),five cores(include three main cores and one neutral and one earthing core; Four main cores and one neutral).The cables can be with armor and without armor.
We can produce cables with PVC outer sheath., flame retardant PVC outer sheath or with fire resistant insulation. The cables are produced according to GB/T12706(eqv IEC 60502) and GB/T18380-2001(eqv IEC60332) or GB/T19216(eqv IEC60331) and or the BS, DIN or other international standards. And we also design and produce cables according to the requirement of our clients.
Application characteristics:
1. Long term working temperature is up to 90℃.
2. The highest conductor temperature is not more than 250℃.(lasting time not over 5 seconds.)
3. Laying temperature not less than 0℃ and the drop height is out of consideration.
4. The cable with chemical stability, anti acid, anti alkali, and oil, anti organic solvent, not easy to be burning.
5. Easy for installation, easy beading and light.
6.Bending ratio as follow
Item | Single core | Three core | ||
Non armor | With armor | Non armor | With armor | |
Min bending radius during installation | 20D | 15D | 15D | 12D |
Near joint box or cable terminal, bending with care and use template. | 15D | 12D | 12D | 10D |
Note:D is the diameter of cable. |
Cable type, name and application
Type | Description | Application | |
Cu | Al | ||
(ZR)YJV | (ZR)YJLV | XLPE insulated and PVC sheathed power cable | Can be laid in indoor, tunnels, cable canal, pipelines and loose soil. Cable should not bear a certain breaking force. |
(ZR)YJY | (ZR)YJLY | XLPE insulated and PE sheathed power cable | |
(ZR)YJV22 | (ZR)YJLV22 | Steel tape armored, XLPE insulated and PVC sheathed power cable | Laid underground, cable can bear mechanic force, but should not bear large breading force. |
(ZR)YJV23 | (ZR)YJLV23 | Steel tape armored, XLPE insulated and PE sheathed power cable | |
(ZR)YJV32 | (ZR)YJLV32 | Steel wire armored, XLPE insulated and PVC sheathed power cable | Laid in water or soil with drop height, the cable can bear mechanic force and large breaking force. |
(ZR)YJV33 | (ZR)YJLV33 | Steel wire armored, XLPE insulated and PE sheathed power cable | |
(ZR)YJV42 | (ZR)YJLV42 | Steel wire armored, XLPE insulated and PVC sheathed power cable | Laid in water or soil with drop height, the cable can bear mechanic force and large breaking force. |
(ZR)YJV43 | (ZR)YJLV43 | Steel wire armored, XLPE insulated and PE power cable |
If you have any need, please share the following information:
insulation material: PVC or XLPE
core number
cross section
with armoure or not, steel tape armoured or steel wire armoured